Archived Design Memos
Last Updated: 12/08/2022 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
21-16 | 06/17/21 | Prestressed-Concrete Structure | IDM Chapter 406, Sections 406-4.02, 406-4.02(01), 406-5.02, 406-5.05, 406-6.0, 406-7.0, 406-7.01 thru 406-7.04, 406-8.01, 406-8.02, 406-9.01 thru 406-9.03, 406-10.0, 406-11.0, 406-12.01, 406-12.03(02), 406-12.03(03), 406-12.05, and 406-12.06 | ||
21-14 | 04/12/21 | Preformed Expansion Joint Filler | IDM Chapter 406, Figures 416-16A, 406-16B, 406-16H, 406-16 I, 406-16 O, 406-16P, and 406-16R
IDM Chapter 409, Section 409-7.06 & Figures 409-2B, 409-2C, 409-2D, 409-2G, 409-3A, 409-3B, and 409-3D IDM Chapter 410, Section 410-5.01(07) |
||
21-13 | 04/12/21 | Pre-Compressed Foam Joint | IDM Chapter 404, Section 404-2.06(03) & Figure 404-2J(new) | ||
21-12 | 04/12/21 | Surface Seal | IDM Chapter 17, Section 17-5.01(03)
IDM Chapter 404, Section 404-2.01 |
||
21-11 | 04/12/21 | Reinforced Concrete Pile Encasement | IDM Chapter 17, Section 17-5.03(02) | ||
21-07 | 03/11/21 | Indiana Design Manual Chapter 14 Updates: Traffic Submittal Updates | IDM Chapter 14, 14-1.02(09) (new), 14-2.06, 14-2.07, and 14-2.08, and Editable Document 103-02-02 | ||
21-06 | 03/11/21 | Indiana Design Manual Chapters 14 and 412 Updates: Bridge Preservation and Bridge Naming Conventions | IDM Chapter 14, Sections 14-2.04 thru 14-2.05 IDM Chapter 412, Sections 412-1.0 thru 412-1.02(02), 412-2.0 thru 412-2.02, 412-2.02(02), 412-2.03(02), 412-3.01(03) thru 412-3.01(05), 412-3.02(04), 412-3.02(06), 412-3.03(08), 412-3.05(07), Figures 412-1A & 412-1B and Editable Documents 103-02-02, 412-02-01, and 412-02-02 | ||
21-02 | 02/04/21 | Mechanically Stabailized Earth (MSE) Walls | 14-2.01(04), 14-2.01(12), 14-2.02(03),14-2.04(03), 14-2.04(09), 14-2.05(03), 14-2.05(04), 410-2.03(01), 410-2.03(03), 410-5.01(05), 410-5.01(06), 410-5.01(07), 410-5.02(01), 410-5.03, 410-6.05(01), 410 -6.07(01), 410-6.07(03), 410-7.01(01), 410-7.01(02), 410-7.02(03), 410-7.04(01), 410-7.05(01), Figs. 410-5(0)A thru C, MSE Wall Design Review Checklist (new) | 17-03 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
20-24 | 11/05/20 | Temporary Pavement Markings | 503-7.03 and 503-7.03(01) | ||
20-23 | 10/08/20 | Field Office Type and Telephone Service | 20-2.03 and Editable Document 14-1C | ||
20-22 | 10/08/20 | Mass Concrete | 405-1.08 and Figure 405-1D | ||
20-21 | 10/08/20 | Unique Special Provision (USP) Submittal Process | None | ||
20-20 | 10/08/20 | Accessible Pedestrian Signal (APS) Studies, Pedestrian Push Buttons, and Curb Ramps | 51-1.06(01), 51-1.06(02), 51-1.06(03), 502-3.03(05), and 502-3.04(05) | ||
20-19 | 09/10/20 | Deleted Figure Placeholder Removal & Editable Documents Naming Conventions | N/A | ||
20-18 Rev. | 09/10/20 rev. 01/07/2021 | Shop Drawing and Falsework Review Procedure | 14-1.02(08) | ||
20-17 | 09/10/20 | Preprint Changes Revisions and Construction Changes | 14-1.02(05) thru 14-1.02(07) and Figures 14-1H thru 14-1N | ||
20-11 | 08/06/20 | Elastomeric Bearing Pads | 409-7.03(03), 409-7.04, 409-7.05, Figures 409-7F, 409-7J, 409-7K (deleted), 409-7L, and 409-7M | ||
20-10 | 07/06/20 | Seed Mix & Mulching Updates | 17-4.10, 17-4.10(01) thru 17-4.10(04), and 17-4.10(06) thru 17-4.10(08) | ||
20-08 | 05/07/20 | End Bent and Pier Diaphragm Details | Figures 406-16A, 406-16B, 406-16D thru 406-16 I, 406-16K thru 406-16N, 409-2C, 409-2D, 409-3A, and 409-3B | ||
20-07 | 05/07/20 | Bulb-Tee Beam Details | Figures 406-14A thru 406-14Z | ||
20-06 | 05/07/20 | Bridge Load Rating Requests | 14-2.04(09), 14-2.05, and 14-2.05(04) |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
19-12 | 10/10/19 | Chapter 503 Maintenance of Traffic | Chapter 81, 82, and 83 | ||
19-09 | 09/05/19 | Preprint Changes | 14-1.02(05) | 20-17 | |
19-07 | 09/05/19 | Pedestrian Fence | 404-4.05 | ||
19-06 | 09/05/19 | Practice Pointers | None | ||
19-05 | 05/06/19 | Guardrail End Treatment and Impact Attenuator Spare Parts Packages | 17-4.12 (deleted) | ||
19-04 | 05/06/19 | End Bent Details | 409-2.04(02) and 409-2.04(03), Figures 409-2A, 409-2C, 409-2D, 409-2E, 409-3A, and 409-3B | ||
19-03 | 05/06/19 | Tooth Joint at Terminal Joints | 409-2.04(01), Figure 409-2F (deleted) | ||
19-02 | 02/08/19 | Shoulder Cross Slope on Single Lane Ramps | 48-5.02, Fig. 48-5B | ||
19-01 | 02/08/19 | Rumble Strips and Rumble Stripes | 45-1.02(06), 502-2.09 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
18-25 | 11/08/18 | Engineering Assessment Manual | None | ||
18-24 | 11/08/18 | Full Depth Reclamation (FDR) Projects and Rule 5 Permits | None | 21-04 | |
18-23 | 10/01/18 | Final Tracings Checklist | 7-1.01(04), 14-1.02(02), 14-1.02(03), 14-1.02(04), 14-2.0 | ||
18-22 | 09/07/18 | Bridge Preventative Maintenance Criteria | Figure 412-1A | ||
18-19 | 08/06/18 | Turn Lane Deceleration Length | Figure 46-4J | ||
18-18 | 08/06/18 | Permanent Taper Rates | Figs. 46-4M, 502-2J, and 502-2L | ||
18-16 | 08/06/18 | Rewrite | Chapter 48 | ||
18-15 | 08/06/18 | Pile Driving | Section 408-3.01 | ||
18-13 | 06/04/18 | INDOT 2018 Standard Drawings | None |
||
18-10 | 05/09/18 | Covering Conflicting Pavement Markings | 83-4.01(03) | ||
18-09 | 05/09/18 | Hydraulic Training Courses | None | ||
18-07 | 03/05/18 | Public Involvement | Ch 8 | ||
18-04 | 03/05/18 | Rectangular Rapid Flashing Beacons (RRFB) | Figure 51-7 O | 18-11 |
|
18-03 | 02/05/18 | IDM Chapters 2, 3, 4, 5, 6 | Ch 2, 3, 4, 5, 6 (deleted) | ||
18-02 | 02/05/18 | Historic Bridge Alternatives Analysis | 14-2.04, 14-2.05, 412-2.03, 412-5.0 | ||
18-01 | 02/05/18 | LPA Pavement Design | 304-5.02 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
17-26 | 12/04/17 | Subgrade Treatment | 17-4.02(01) | ||
17-25 | 11/06/17 | Bridge Load Rating for Design-Build Projects | None |
Sections 14-1.02, 14-2.04(09), 14-2.05, 14-2.05(04) | |
17-24 | 10/02/17 | Curb Ramp Design Reminders | None |
||
17-22 | 10/02/17 | Survey SS4 Deliverables | 26-1.0 |
Section 26-1.0 | |
17-21 | Unassigned | ||||
17-15 | 07/07/17 | Detour Signs | None |
||
17-14 | 07/07/17 | Fluorescent Yellow Sheeting for Warning Signs |
502-1.03(08) |
||
17-13 | 06/12/17 | HEC-RAS 5 and INDR Construction in a Floodway Permit Application Guidance | None |
||
17-12 | 05/30/17 | Foundation Review Fom Submittal |
Sections 14-2.04(06) and 14-2.04(09) | ||
17-11 | 05/16/17 | INDOT 2017 Standard Drawings | None |
||
17-09 | 05/01/17 Rev. 05/11/17 |
Panel Sign Wide Flange Post Selection and Plan Detailing | Section 502-1.01(05) | ||
17-08 | 04/21/17 | 2017 Interstate Highways Congestion Policy (IHCP) |
None |
Interstate Highways Congestion Policy Exception Preparer Training | |
17-07 | 04/12/17 | Hydraulic Design for Small Structures, Bridges, and Inlets | Sections 203-2.02, 203-3.03, 203-4.04 and Fig. 203-2A and 203-2B |
|
|
17-06 | 04/06/17 | Bridge Load Rating Requests for Design Submittals | None |
||
17-05 | 04/05/17 | Exceptions to Bridge Load Rating and Posting Policy | None |
|
|
17-03 | 03/01/17 | Mechanically Stabilized Earth (MSE) Walls | Sections 402-6.02(02), 409-2.04(02), 409-3.03, Figures 409-2G and 410-5(0)C (New) | Sections 402-6.02(02), 409-2.04(02), 409-3.03, Figures 409-2G and 410-5(0)C (New) | 21-02 |
17-01 | 01/10/17 | Final Tracings Checklist | None |
|
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
16-37 | 12/07/16 | Changes to Final Tracings after Advertisement | Section 14-1.02(05), item 2d.(1) | ||
16-36 | 11/29/16 | Pedestrian Pushbutton Assemblies Plan Details Required for New and Relocated Assemblies | Section 51-1.06, Figures 51-1P thru 51-1T and 502-3.03(05) item 4 |
Section 51-1.06, Figures 51-1P thru 51-1T, 502-3.03(05) item 4 |
|
16-34 | 09/22/16 | Culvert Design Using HY-8 | None |
||
16-33 | 09/19/16 | Sidewalk Width on Bridges | Sections 45-1.06(02), 51-1.03(02), 402-6.02(01), Figure 402-6P and 404-4D |
Sections 45-1.06(02), 51-1.03(02), 402-6.02(01), Figures 402-6P and 404-4D | |
16-32 | 09/19/16 | Integral End Bent Depth | Section 409-2.04(02), Figures 409-2C and 409-2D |
Section 409-2.04(02), Figure 409-2C and 409-2D |
|
16-31 | 09/15/16 | Fiber Reinforced Polymer Composite Materials | Section 412-3.05(05) |
||
16-30 | 08/19/16 | Quantity Calculations for Slip Lining of Existing Pipe | None |
||
16-29 | 07/20/16 | Final Tracings Checklist | None |
||
16-28 | 07/14/16 | Traffic Forecasting and Crash Data | Sections 5-2.02 and 56-3.01 |
||
16-27 | 07/14/16 | Temporary Erosion and Sediment Control Plan Development | Sections 205-2.0 thru 205-5.0 and Figure 205-1A |
||
16-26 | 07/01/16 | Underdrain Outlet Protectors | Figure 304-18A |
||
16-25 | 06/29/16 | HMA Pavements - ESAL Categories and HMA Type A | Figure 304-15A and 304-15B |
||
16-24 | 06/02/16 | PSE Checklist for Bundled Projects | None |
||
16-23 | 06/02/16 | Pedestrian Crossing Treatments | Section 51-7.09 and Figure 51-7 O |
||
16-22 | 05/26/16 | Seeding Application Rates | Sections 17-4.10(01) thru 17-4.10(04) |
||
16-21 | 05/20/16 | Semi-Smooth Pipe Interior Designation | 203-2.02(13) and Figure 203-2F |
||
16-20 | 05/13/16 | Final Tracings Checklist | None |
||
16-19 | 05/13/16 | In-Kind Culvert Replacement Policy | Section 203-2.02(02) |
||
16-18 | 04/18/16 | Railroad-Highway Crossing Warning Division | Section 47-1.05, Figure 47-1A |
Policy for Railroad-Highway Grade Crossing Warning Devices, Section 47-1.05, Figure 47-1A |
|
16-17 | 04/15/16 | Median Barrier | Sections 45-2.01, 45-2.02(03), 49-3.08, 49-4.01(04), 49-6.04(01) |
||
16-15 | 04/08/16 | INDOT 2016 Standard Drawings | None |
||
16-14 | 04/07/16 | Value Engineering | 50-3.0 |
||
16-13 | 03/24/16 | Indiana Design Manual Rewrite | Chapter 72 and Section 14-2.05 |
||
16-12 | 03/21/16 | Curb Ramps and Sidewalks | 51-1.0 through 51-11.0, Figures 51-1A through 51-1 O, 40-8.04(01), 45-1.06(02), 46-11.02(04) and 46-11.02(07) |
IDM Chapter 51, Sections 40-8.04(01), 45-1.06(02), 46-11.02(04), and 46-11.02(07) |
|
16-11 rev. | 03/17/16 Rev. 09/12/16 |
Temporary Erosion and Sediment Control | None |
PSE Checklist |
20-05 |
16-09 | 03/16/16 | Bridge Deck Drains | None |
||
16-08 | 03/11/16 | Shop Drawing Review | 14-1.02(08) | ||
16-07 | 03/11/16 Rev. 11/21/16 |
Plan Sheet Size and Changes to Final Tracings | 14-1.02(02), 14-1.02(04) through 14-1.02(07), and 14-3.03 |
Sections 14-1.02(02), 14-1.02(04) through 14-1.02(07), and 14-3.03 |
|
16-06 | 03/08/16 | Portable Signals | 83-5.0 | ||
16-05 | 03/08/16 | Coordination of Bridge Inspection during Construction | None |
||
16-04 | 01/28/16 | Designer Summary of Required Utility Relocation - Project Design and Utility Summary | None | ||
16-03 | 01/12/16 | Lighting Design Procedure | 504-4.02(03) through 502-4.07, and Figures 502-4D, 502-4P, and 502-4S |
Section 502-4.02(03) through 502-4.07, Figures 502-4D, 502-4P, 502-4S |
|
16-02 | 01/08/16 | Accessible Pedestrian Signals (APS) | 502-3.03(02) through 502-3.04(05) |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
15-20 | 11/04/15 | Curb Ramp Plan Details | 51-1.04 through 51-1.08 | 16-12 | |
15-19 | 09/04/15 | Durable Pavement Markings used for Longitudinal Lines | 502-2.01(03) and Figure 502-2C | Section 502-2.01(03), Figure 502-2C | |
15-18 | 08/17/15 | Performance Evaluation Guidelines | None | ||
15-17 | 08/10/15 | Contract Questions Prior to Letting | None | ||
15-16 | 07/20/15 | ERMS File Naming Conventions and Email Notification | None | ||
15-15 | 07/09/15 Rev. 07/25/17 |
Worksite Increased-Penalty Signs | 83-2.05 | ||
15-14 | 07/07/15 | Geotechnical Information for MSE Walls | None | ||
15-13 | 06/10/15 | Waterway Permits Manual | None | ||
15-12 | 05/22/15 | Design Resources | None | ||
15-10 | 04/13/15 | INDOT 2015 Standard Drawings | None | ||
15-09 | 04/13/15 | INDOT Storm Water Management Field Guide | None | ||
15-07 | 03/23/15 | Proprietary Materials | None | ||
15-06 | 03/23/15 | Temporary Seeding and Mulching |
17-4.10(03) and 205-3.02(03) | Section 17-4.10(03) | 16-16 |
15-05 | 03/23/15 | ERMS Naming Convention and Contract Preparation Document | 14-1.02(06) | ||
15-04 | 03/23/15 | Structure Backfill and Flowable Backfill |
17-2.08 | Section 17-2.08 | |
15-03 | 03/13/15 | Utility and Railroad Coordination Certification | None | 17-09 | |
15-02 | 02/06/15 | Safety Edge | None | Figure 304-21X | |
15-01 | 02/05/15 | Utility and Railroad Coordination Certification | 104-1.04(04), 104-1.05, and 104-2.01, Figure 14-1C |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
14-14 | 10/23/14 | Flood Control Act Amendment |
None | ||
14-13 | 09/12/14 | Tracings Checklist & PS&E Narrative | Figures 14-1E, 14-1E(1), 14-1E(2), 14-1E(3) | ||
14-12 | 07/02/14 | 2014 Interstate Highways Congestion Policy (IHCP) | None |
|
|
14-11 | 07/01/14 | Interstate Vertical Clearance | 40-8.04(03) Figure 40-8A |
||
14-09 | 05/13/14 | Bridge Railing Offset | 402-6.02(01), Figure 402-6H |
402-6.02(01), Figure 402-6H |
|
14-08 | 05/07/14 | Bridge Preservation | 72-1.04, 72-2.05(02), 72-3.01(02), and 72-6.02. Figure 72-2D (new) | Section 72-1.04, 72-2.05(02), 72-3.01(02), 72-6.02, Figure 72-2D | 16-13 |
14-07 | 04/23/14 | Railroad-Highway Crossing Train-Activated Safety Devices | Ch. 47 | ||
14-06 | 04/17/14 | Indiana Design Manual Rewrite Chapter 304 | Ch. 52 | ||
14-04 | 03/27/14 | Subgrade Treatment | 17-4.02(01) | Section 17-4.02(01) | 17-26 |
14-03 | 02/21/14 | Alterations Which Require ADA Curb Ramps | 40-8.02(01), 40-8.04(01), 51-1.08, 56-2.0, 56-4.06(06), 56-4.09(01), 56-4.09(02), Figures 51-1 I and 56-4F | 40-8.02(01), 40-8.04(01), 51-1.08, 56-2.0, 56-4.06(06), 56-4.09(01), 56-4.09(02), Figures 51-1 I and 56-4F | |
14-02 | 02/07/14 | Q500 Scour Policy | 202-3.03 | ||
14-01 | 02/04/14 | Indiana Design Manual Rewrite | Ch. 75, Ch. 76, Ch. 77, Ch. 78 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
13-18 | 10/15/13 | Pavement Design | 52-8.03, 52-8.03(01), Figures 52-8A, 52-8B, 52-8C | Sections 304-14.0, 304-14.01, Figures 304-14A, 304-14B, 304-14C | |
13-17 | 08/15/13 | Location Control Route Survey (LCRS) and LCRS Plat | 26-2.0, Figure26-2D | Section 26-2.0, Figure 26-2D | |
13-16 | 08/15/13 | Survey Transmittal Deliverables Related to Geo-Coordinated Survey | 26-1.01 | Section 26-1.01 | |
13-15 | 08/14/13 | HMA Pavement Pay Items for 2014 Standard Specifications Section 402 | None | Mixture Type Conversion Table, USP HMA |
16-25 |
13-14 | 08/13/13 | Indiana Design Manual Rewrite | Ch. 10, Ch. 11, 402-5.05, 402-5.06, 402-6.01(03) | ||
13-13 | 07/26/13 | Centerline and Edge Line Rumble Stripes | 45-1.02(06), 76-3.02(05), 76-3.02(06) | Section 45-1.02, 76-3.02(05), 76-3.02(06) | |
13-12 | 06/12/13 | Lighting Design Procedure | 78-3.04, 78-5.0, 78-6.0, 78-7.0 | Section 78-3.04, 78-5.0, 78-6.0, 78-7.0 Fig 78-5B, Fig 78-5C |
|
13-11 | 05/29/13 | Indiana Design Manual Errata and Editorial Revisions | See Memo | ||
13-08 | 03/27/13 | Indiana Design Manual Rewrite | Ch. 18 | ||
13-07 | 03/27/13 | Signal Display | 77-4.05 | Section 77-4.05 | 14-01 |
13-06 | 03/27/13 | Signal Electrical System | 77-5.05 | Section 77-5.05 | 14-01 |
13-05 | 03/04/13 | In-Kind Replacement Policy | 203-2.02(02) | Section 203-2.02(02) | |
13-04 | 03/04/13 | Flowline Elevation, Pipe Material Selection |
203-2.02(10) 201-1.05 thru 1.08 Figs 201-1A thru 201-1G |
Section 203-2.02(10) Section 201-1.05 thru 1.08 and figures |
|
13-03 | 02/08/13 | 2013 Interstate Highways Congestion Policy (IHCP) | 82-6.03 | 14-12 | |
13-02 | 01/25/13 | INDOT CAD Standards Manual | Ch. 15 | CAD Standards Style Sheet | |
13-01 | 01/07/13 | Indiana Design Manual 2013 Edition | See memo | IDM Chapter Reorganization |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
12-22 | 10/05/12 | Indiana Design Manual Rewrite | Ch. 205 | ||
12-20 | 09/26/12 | AASHTO LRFD Bridge Design Specifications 2012, affects on Indiana Design Manual | See memo | Part 4 Revisions | |
12-19 | 08/24/12 | Final Tracings Checklist, FHWA PSE Checklist | 14-1.02 Fig 14-1E Fig 14-1E(1) Fig 14-1E(2) Fig 14-1E(3) |
Ch. 14-1.02 Fig 14-1E Fig 14-1E(1) Fig 14-1E(2) Fig 14-1E(3) |
14-13 |
12-18 | 07/18/12 | Indiana Design Manual Rewrite | Ch. 201, 202, 203 | ||
12-17 | 07/06/12 | Plans-Sheets Size | 14-3.03 | ||
12-16 | --- | Memo rescinded | |||
12-15 | 06/08/12 | Microsurfacing | 52-11.01, item 4 | RSP 411-R-432 | 14-06 |
12-14 | 06/08/12 | Radio Communication Interconnection | 77-6.03 | Fig 77-6A | |
12-13 | 06/08/12 | Traffic-Signal Loop Tagging Table | 77-5.09(03) | ||
12-12 | 06/06/12 | Reinforced-Concrete Bridge Approach | 17-5.09 | RSP 609-B-199 RSP 706-R-600 Fig 17-5G Fig 17-5G(1) Fig 17-5G(2) |
|
12-11 | 06/06/12 | Fluorescent-Yellow Sign Sheeting | 75-4.07 | 802-SNGS-05 | |
12-10 | 06/06/12 | Work-Site Speed Limit | 83-2.03(01) | RSP 801-C-228 | |
12-09 | 06/06/12 | Bridge Railings | Figures 404-4B, 404-4C | RSP 706-B-197 Fig 404-4B Fig 404-4C |
|
12-08 | 05/17/12 | Mechanically-Stabilized-Earth Retaining Wall Design | 410-5.01(06), (07) | RSP 731-R-597 Fig 410-5(0)A Fig 410-5(0)B |
|
12-07 | 05/15/12 | Portable Changeable Message Sign | 83-2.06 | RSP 801-C-229 Fig 83-2E |
|
12-06 | 04/26/12 | Plans-Sheet Size | 14-3.03 | ||
12-05 | 03/14/12 | Bridge Condition Appraisal Report Submittal - Content and Order | 72-2.05 | ||
12-04 | 03/01/12 | Design Exception Level One Request Routing and Approval | 40-8.04(01) | Fig 40-8C | |
12-03 | 02/21/12 | Stage 3 Plans-Review Submission | 14-2.01 | ||
12-02 | 02/16/12 | Pipe Lining | 31-4.05(06) | 12-18 | |
12-01 | 01/06/12 | Indiana Design Manual Rewrite | See memo |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
11-25 | 12/22/11 | Ultrathin Bonded Wearing Course | 52-11.01 item 5 | RSP 414-R-590 | 14-06 |
11-24 | 12/22/11 | Microsurfacing | 52-11.01 item 4 | RSP 411-R-432 | 12-15 |
11-23 | 11/22/11 | Traffic-Signal Cantilever Structure | 77-4.03 77-4.04 |
RSP 805-T-169 RPD 805-T-177d RSP 922-T-168 |
|
11-22 | 10/25/11 | Structural Steel Cleaning and Painting | 17-5.11, 17-5.11(04), 17-5.11(95) | 619-PRWS-01 | |
11-21 | 10/19/11 | Signal Conduit | 77-5.05 | 13-06 | |
11-20 | 10/28/11 | Traffic-Signal Cantilever Structure | 77-4.03, 77-4.04 | RSP 805-T-169 RSP 922-T-168 RPD 805-T-177d |
11-23 |
11-19 | 09/20/11 | Fish and Wildlife Review, and Environmental Consultation Form | 14-2.01 14-2.04 |
||
11-18 | 09/15/11 | Pavement Markings | 76-3.02 Fig 76-3A |
Fig 76-3A | |
11-17 | 09/07/11 | Non-Participating Pay Items | 20-2.02(04) | ||
11-16 | 08/18/11 | Specialty Drainage Structures | 31-4.05 (203-2.05) 31-4.06 (203-2.06) |
12-18 | |
11-15 | 08/18/11 | Proprietary-Material Use | 17-1.05 | ||
11-14 | 08/17/11 | Use of U.S. Survey Foot | 22-5.01 | ||
11-13 | 08/17/11 | Structural Steel Cleaning & Painting | 17-5.11, 17-5.11(04), 17-5.11(05) | E619-PRWS-01 | 11-22 |
11-11 | 07/08/11 | Right-Of-Way Certification | 14-2.01(12) | ||
11-10 | 07/08/11 | Bridge-Approach Guardrail and End Treatments | 49-4.02(01) 49-4.02(04) 49-8.01(04) 49-9.02 |
||
11-08 | 04/05/11 | InRoads Survey Format | Ch. 22, 23, & 26 | ||
11-07 | 03/28/11 | High-Tension Cable-Barrier System (CBS) | 45-5.01(04) | RSP 624-R-546 RPD 627-R-546d |
11-09 |
11-06 | 03/07/11 | Bridge-Scour-Analysis Q500 Discharge Determination | 32-6.07 | 12-18 | |
11-05 | 03/04/11 | Revised Indiana Design Manual | See memo | ||
11-04 | 01/24/11 | New Consultant Performance Evaluation Manual | None | 15-18 | |
11-03 | 01/24/11 | New Consultant Performance Evaluation Manual | None | 15-18 | |
11-02 Withdrawn |
01/07/11 | Non-Participating Pay Items | |||
11-01 | 01/07/11 | Use of AASHTO LRFD Bridge Design Specifications | 12-21 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
10-30 | 12/06/10 | Inputting Data for Cost Estimate | 20-2.01 | ||
10-29 | 11/22/10 | Pavement-Marking Materials | 76-3.0 | ||
10-28 | 11/22/10 | Construction-Zone Reduced-Speed-Limit Sign | 83-2.03(01) item 7 | 801-T-174d | |
10-27 | 11/22/10 | Wireless Vehicle-Detection System & Decision-Making Criteria | 77-4.02(03) | Fig 10-27A Fig 10-27B 805-T-173 805-T-173d |
|
10-26 | 11/16/10 | Structural-Member Fillet Treatments | Figs 61-4B, 61-4C | Fig 61-4B Eng Fig61-4B Met Fig 61-4C Eng Fig 61-4C Met |
|
10-25 | 10/29/10 | Department-Personnel Project-Site Use of Cellular Telephones or Radios | None | 628-C-164 | |
10-24 | 10/14/10 | Final Tracings Checklist | 14-1.02(03) items 23 & 24, Figure 14-1E | 14-1.02(03) Fig 14-1E |
12-19 |
10-23 | 10/05/10 | Pavement-Marking Materials | 76-3.0 | 10-29 | |
10-22 | 09/10/10 | Plans Title Sheet | None | Fig 10-22A | |
10-21 | 09/02/10 | Lane-Shift & Merging Tapers | Figs 46-4M, 76-2B, 45-4A | Fig 46-4M Eng Fig 46-4M Met Fig 76-2B Eng Fig 76-2B Met |
|
10-20 | 08/24/10 | High-Mast Lighting Design | 78-7.0 | 920-T-162 | |
10-19 | 07/29/10 | Culvert Sumping | 31-3.04(07) | RSP 723-R-568 RPD 723-R-569d |
|
10-18 | 07/09/10 | Bridge Construction-Loads Considerations | 60-3.10 | Fig 10-18Eng Fig 10-18Met |
|
10-17 | 05/26/10 | Adjacent Prestressed-Concrete Box Beams Transverse Connection | 63-8.01 | 707-BPBB-01 707-B-183 |
|
10-16 | 04/28/10 | Joint Transportation Research Project (JTRP) SPR-2853 regarding IDEM Rule 5 Permitting, Water Quality, Notice of Intent, & Notice of Termination | See Memo | Fig 14-1A | |
10-15 | 04/22/10 | Subgrade-Treatment Types | 17-4.02(01) | RSP 207-R-577 | 14-04 |
10-14 | 04/22/10 | Pavement or Overlay Performance Criteria Pavement Engineering Webpage |
Fig 52-8B, 52-8C | 13-18 | |
10-13 | 04/13/10 | Select & Non-Select Historic Bridges | 72-7.01 | ||
10-12 | 04/06/10 | ERMS File Title-Naming Conventions | 14-1.02(04) 14-1.02(06) |
||
10-11 | 03/26/10 | Test Piles | 17-5.03 | RSP 701-B-132 | |
10-10 | 03/16/10 | Nonmotorized-Vehicle-Use Facility Pavement Sections | 51-7.06 | RSP 207-R-575 RPD 402-R-571d RPD 402-R-572d RPD 502-R-573d |
|
10-09 | 03/04/10 | Project Commitment Report | 14-2.01 14-2.02 14-2.04 |
||
10-08 | 02/25/10 | Temporary Seed Mixtures | 17-4.10(02) | ||
10-07 | 01/29/10 | Mitigation-Sites Information on Right-of-Way Plans | See memo | ||
10-06 | 01/14/10 | Joint Transportation Research Project (JTRP) SPR-2853 | See memo | 10-16 | |
10-05 | 01/11/10 | Plans-Sheets Sizes | 14-3.03 | ||
10-04 | 01/05/10 | Mechanically-Stabilized-Earth Retaining-Wall Bridge Abutment | 59-2.02(01) item 3 | ||
10-03 | 01/05/10 | Flanking-Inlet Locations | Fig 36-10E | ||
10-02 | 01/05/10 | Bridge-Railing Types | Fig 61-6B | ||
10-01 | 01/05/10 | Bridge-Railings Test Levels | English-Units Figs 49-6D(40) & 49-6D(45), 61-6.01 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
09-33 | 12/14/09 | Modification Project Which Requires American Disability Act (ADA) Component Upgrades | 51-1.08 | ||
09-32 | 12/23/09 | Environmental Consultation Form | Figs 7-3A & 7-3B | ||
09-31 | 12/18/09 | Pay-Items List | Figure 20-2A | ||
09-30 | 12/18/09 | Modern Roundabouts | 51-12.0 | ||
09-29 | 12/16/09 | Use of Flashing Beacons with Signs | 77-3.02, 77-3.04 | RSP 805-T-169 RPD 805-T-169d |
|
09-28 | 12/14/09 | Project Commitment Database IMplementation, ERMS Project File Naming Conventions | 7-1.01(05) | Fig 09-28A Fig 09-28B |
|
09-27 | 12/04/09 | Culvert Sumping | 31-3.04(07) | 10-19 | |
09-26 | 11/30/09 | Sign-Sheeting Material & Overhead-Sign Lighting | 75-2.02, 75-2.03 item 1 | RSP 802-T-171 RPD 802-T-171d |
|
09-25 | 11/12/09 | Bridge Superstructure Surface-Seal Limits | 17-5.01, 61-4.01 | Fig 09-25A | |
09-24 | 11/10/09 | Positive Protection in Work Zone | 82-4.01 | ||
09-23 | 11/10/09 | Shop-Drawings Submittal, & Stage 3 Right-of-Way Change | 14-1.02(07) Item 3, 14-2.01(12) Item 1 | ||
09-22 | 11/04/09 | Bridge Load Rating | PDP 14-2.04(08) Item 13, 14-2.05(04); Non-PDP 14-2.03(07) Item 9, 14-2.04(04) | ||
09-21 | 09/21/09 | Proprietary Materials | 17-1.05, Fig 17-1A | ||
09-20 | 09/16/09 | Bridge-Railings Test Levels | English Figs 49-6D(40) & 49-6D(45), & 61-6.01 | ||
09-19 | 09/15/09 | Final Tracings Checklist | PDP Figure 14-1E | ||
09-18 | 09/02/09 | Sidewalk-Project Plans Development | 51-1.05 | ||
09-17 | 08/21/09 | Project Commitment Database Procedure | 7-1.01(05) | 09-28 | |
09-16 | 07/24/09 | Geotechnical Foundation Review | 66-1.05(02) & Figure 66-1A | ||
09-15 | 06/12/09 | Geotechnical Foundation Review | 66-1.05(02), Figure 66-1A | ||
09-14 | 05/18/09 | Three or Four-Sided Drainage Structures | 31-4.05 | 11-16 | |
09-13 | 05/08/09 | Overhead Box-Truss Sign Structures and Foundations | 75-6.01 | ||
09-12 | 05/07/09 | Piling | 66-3.02(01), 67-1.03 | Fig 09-12A Fig 09-12B RSP 701-B-182 |
|
09-11 | 04/29/09 | Moment Slab Near Top of Mechanically-Stabilized-Earth Retaining Wall | 17-4.01, 45-1.02 | ||
09-10 | 04/21/09 | Nonmotorized–Vehicle–Use Facility | 51-7.0 | ||
09-09 | 03/27/09 | Proprietary Material or Product Use | 17-1.05, 19-3.01 | ||
09-08 | 03/26/09 | Bridge-Painting Information | Figure 17-5K | ||
09-07 | 03/17/09 | Chapter 19 | Chapter 19 | ||
09-06 | 03/16/09 | Pavement Design in Accordance with the Mechanistic Empirical Design Pavement Design Guide (MEPDG) | Chapter 52 | 13-18 | |
09-05 | 02/06/09 | Low Channel-Clearing Elevation | 59-1.04, item 5 | ||
09-04 | 01/27/09 | Sign-Sheeting Material | RSP 802-T-171 | 09-26 | |
09-03 | 01/16/09 | Masonry Coating | |||
09-02 | 01/13/09 | Superelevation Runoff Length | 43-3.03(01), 49-3.03(02) | ||
09-01 | 01/09/09 | Figure 29-8A | Figure 29-8A |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
08-22 | 12/29/08 | Figs 59-1E, 1F, 1G | Figs 59-1E, 1F, 1G | ||
08-21 | 10/28/08 | Semi-Integral End Bents | 67-1.01 | RSP 702-B-178 Fig 67-1C1 Eng Fig 67-1C2 Eng Fig 67-1C3 Eng Fig 67-1C1 Met Fig 67-1C2 Met Fig 67-1C3 Met |
|
08-20 | 09/11/08 | Bridge Plans Title Sheet | 14-2.04, 14-2.05 | Two-Sheet Format | |
08-19 | 09/03/08 | Details for Structural-Member Fillets | Figs 61-4B, 61-4C | ||
08-18 | 08/25/08 | Use of Recurring Special Provisions Menu | 19-3.0 | ||
08-17 | 08/06/08 | Overhead Sign Trusses | 75-2.06 | ||
08-16 | 08/06/08 | Project Commitment Database Procedure | 7-1.01(04) | 09-28 | |
08-15 | 07/25/08 | Minimum Pile Length & Integral End Bents | 66-3.03 & 67-1.0 | Fig 67-1B Eng Fig 67-1B Met Fig 67-1C Eng Fig 67-1C Met |
|
08-14 | 06/26/08 | New or Revised Contract Document Submittal | PDP 14-2.01(14), non-PDP 14-2.01(03) | Fig 08-14A | |
08-13 | 06/16/08 | Painting Structural Steel | 17-5.11 | RSP 619-B-177 | |
08-12 | 05/29/08 | Stable Construction Entrances | 37-2.0 | RSP 108-C-192 | |
08-11 | 05/30/08 | Project Field Office | 14-1.02(03) | RSP 628-R-552 | |
08-10 | 05/19/08 | Construction, Maintenance, and Inspection Manual for Major or Complex Bridge | 70-1.0 | ||
08-09 | 05/19/08 | AASHTO LRFD Table Correction | |||
08-08 | 05/16/08 | High-Tension Cable Barrier System | 17-3.14 & 49-4.06 | RPD Eng. 627-R-546d RSP 627-R-546 |
|
08-07 | 05/16/08 | Property-Owner Contact for Condemned Parcels | 85-1.08 | ||
08-06 | 04/18/08 | Temporary Pavement Markings | 83-4.0 | 801-T-165 | |
08-05 | 03/18/08 | Temporary Seeding | 17-3.10(04) | ||
08-04 | 03/18/08 | Bridge Load Rating | PDP Chapter 14 Sections 14-2.04(08) Item 13, Section 14-2.05(04); Non-PDP Chapter 14 Sections 14-2.03(07) Item 9, Section 14-2.04(04) | 09-22 | |
08-03 | 03/18/08 | Federal Aviation Administration (FAA) Tall-Structure Permit | 9-3.02 | ||
08-02 | 03/18/08 | Use of Indiana Design Manual, English-Units Version | ALL | ||
08-01 | 03/18/08 | Use of AASHTO LRFD Bridge Design Specifications & Indiana Design Manual Part VI, Structural Design | Part VI | 11-01 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
07-14 | 12/21/07 | Plan Development Process | Chapter 14 | ||
07-13 | 10/16/07 | Structure Backfill & Flowable Backfill | 17-2.09 | 211-R-543 213-R-446 |
15-04 |
07-12 | 10/16/07 | Pipe-Material-Selection Computer Program | |||
07-11 | 08/28/07 | Contract-Preparation Documents to Contract Administration Division | 14-1.02(03) | Utility Cert Utility Waiver Commitments |
|
07-10 | 07/26/07 | Worksite Increased-Penalty Signs | 82-3.05 | RPD Eng. 801-R-542d RPD Eng. 801-R-543d R RPD Eng. 801-R-544d RPD Met. 801-R-542d RPD Met. 801-R-543d RPD Met. 801-R-544d |
15-15 |
07-09 | 04/24/07 | Rational-Method Formula for Determining Peak Rate of Runoff | 29-8.04 | ||
07-08 | 04/12/07 | Impact Attenuator Type CR | 49-6.01 | ||
07-07 | 04/12/07 | Bridge Bearing Pads | 67-4.03 | ||
07-06 | 03/22/07 | Patching Concrete Structures | 72-3.04(03) | RSP 710-B176 | |
07-05 | 03/22/07 | Treatment of Historic Bridge on Low-Volume Local Road | 72-7.0 | ||
07-04 | 02/06/07 | Backfilling & Video Inspection for Drainage Structures | 17-2.9 | RSP 211-R-534 714-R-535 715-R-536 717-R-537 904-R-538 RPD Eng. 715-R-536d RPD Met. 715-R-536d |
|
07-03 | 01/29/07 | ADA Responsibilities Associated with Sidewalk Improvements | 51-1.08 | ||
07-02 | 01/23/07 | Roadside Location of Guardrail, Guardrail End Treatments, Impact Attenuators, Light Standards, & Breakaway Sign Supports | 49-3.06 | ||
07-01 | 01/02/07 | Contract-Preparation Documents to Contract Administration Division | 14-1.02(03) |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
06-18 | 12/27/06 | Part VI, Structural Design | Part VI | 08-01 | |
06-17 | 12/08/06 | Traffic Signal Equipment to be Removed | See Memo | ||
06-16 | 12/08/06 | Structural-Members Unit Prices | Fig 59-5A | ||
06-15 | 12/08/06 | Prestressed-Concrete Box Beam Details | Figs 63-15A through 63-15R | ||
06-14 | 11/06/06 | Structural Expansion Joints | 61-4.06(03) | RSP 724-B-046 | |
06-13 | 09/27/06 | Design Memoranda in Website Listing | varies | ||
06-12 | 09/20/06 | Transformed Beam Section | 63-4.01 | ||
06-11 | 09/15/06 | Policy for Geotechnical Investigation or Geotechnical Waiver | 18-1.0 | Geotechnical Policy | |
06-10 Adv 06-10 Pol |
09/14/06 | Blue-Retroreflectors Raised Pavement Markers | 76-3.02(05) | ||
06-09 | 09/14/06 | Linear Grading | 17-2.06 | RSP 203-R-260 | |
06-08 | 09/01/06 | Contract-Preparation Documents to Contract Administration Division | 14-1.02(03) | 07-01 | |
06-07 | 08/29/06 | High-Performance Structural Steel | 64-2.01(01) | RSP 711-B-165 | |
06-06 | 08/18/06 | Interior Diaphragms with Prestressed-Concrete Members | 63-7.02 | RSP 707-B-171-172-173 RPD Eng. 707-B-173d RPD Met. 707-B-173d |
|
06-05 | 08/03/06 | Level One Design Exception Approval Procedure | 40-8.04 | ||
06-04 | 08/03/06 | Temporary Revetment Riprap Check Dam | 37-3.03(01) | 205-R-528 RSP & RPD | |
06-03 | 06/01/06 | Development of Bridge Plans | 14-2.03 14-2.04 | ||
06-02 | 04/25/06 | Pay Unit for Water Pay Items | 17-3.10(07) | ||
06-01 | 04/25/06 | Final Quantities Values | 17-1.03 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
05-38 | 12/21/05 | Errata Corrections to the Indiana Design Manual | Varies | ||
05-37 | 11/28/05 | Shoulder Cross Slope & Pavement Section | Varies | Ch.52 Met.Figs Ch.53-54 Met.Figs Ch.55 Met. Figs |
|
05-36 | 11/22/05 | English-Units Indiana Design Manual & Additions & Corrections to Manual | Varies | ||
05-35 | 11/14/05 | Snowplowable Raised Pavement Marker Castings | 76-3.02(05) | RSP 808-T-151 | |
05-34 | 11/09/05 | Concrete Railings & Moment Slabs at Mechanically Stabilized Earth (MSE) Wall Systems | 49-4.01(05) | 706-R-504 RSP & RPD | |
05-33 | 09/23/05 | New & Revised Editable Design Manual Documents | Varies | ||
05-32 | 09/23/05 | New Estimator Software Pay Item List | 20-2.03 | ||
05-31 | 09/09/05 | Public Road Approaches & Drives | 46-11.0 | RSP 610-R-502 | |
05-30 | 09/01/05 | Bridge Deck Overhang Width | 61-5.02 | ||
05-29 Adv 05-29 Pol |
09/01/05 | Curbed Section in Suburban or Intermediate Urban Area | Ch 53, 55 | ||
05-28 | 08/26/05 | Geometric Design Criteria for Recreational Roads | Fig 51-6B | Fig 51-6B | |
05-27 | 07/28/05 | Inputting Data for Cost Estimate | 20-2.01 | Input Form | 10-30 |
05-26 | 07/28/05 | Bridge Identification in Pay Item Names | 20-2.02(03) | ||
05-25 | 07/28/05 | Earthwork Quantities for Retaining Walls | 17-4.05(02) | 17-4.05(02) | |
05-24 | 07/08/05 | Design Memoranda in Website Listings | Varies | ||
05-23 | 07/08/05 | 2006 INDOT Standard Specifications Book | |||
05-22 | 07/08/05 | Seed Mixture CV | 17-3.10 | ||
05-21 | 06/27/05 | New or Revised Access to the Interstate System | 48-1.03 | ||
05-20 | 06/27/05 | Shoulder Width of Multi-Lane Urban Arterial | Table 53-6 | ||
05-19 | 06/27/05 | HMA Ramp Cross Section | Fig 52-13S, Fig 52-13T | Fig 52-12S & 52-12T |
14-06 |
05-18 | 06/27/05 | Mitigation Commitments | 7-1.01(04) | 08-16 | |
05-17 | 06/13/05 | Impact Attenuator Spare Parts Package | 49-6.01 | RSP 601-R-497 | |
05-16 | 06/02/05 | Guardrail End Treatment Spare Parts Package | 49-5.04(01) | RSP 601-R-237 | |
05-15 | 05/26/05 | Temporary Traffic Barrier (TTB) | 82-4.02(03) | ||
05-14 | 05/26/05 | Use of Indiana Design Manual Part VI, Structural Design | Varies | 06-18 | |
05-13 | 05/26/05 | Development of Bridge Plans | 14-2.03, 14-2.04 | 06-03 | |
05-12 | 05/26/05 | Relationship Between Guardrail End Treatment & Guardrail Length of Need | 49-5.04(04) | ||
05-11 | 05/26/05 | New Geotechnical Instrumentation | 18-1.02 | ||
05-10 | 05/26/05 | Level One Checklist for S-Lines | 14-2.0 | ||
05-09 | 05/26/05 | Use of Integrated Traffic System (ITS) Controllers | 77-4.01(06) | ||
05-08 | 04/14/05 | ESALs or HMA mixtures, Fig 52-9B | 52-9B | 14-06 | |
05-07 | 03/28/05 | Maximum allowable stress in H-piles | 66-3.02(02) | ||
05-06 | 03/15/05 | Prime coat, 52-9.02(11) | 52-9.02(11) | 14-06 | |
05-05 | 02/28/05 | NCHRP Bridge Railings & Transitions | 61-6.01 | ||
05-04 | 02/08/05 | Vertical Alignment for 3R Project | 55-4.04 | ||
05-03 | 02/01/05 | Status of Design Memorandum | 05-24 | ||
05-02 | 01/19/05 | Truck-Height Barrier | 49-5.02(01) | ||
05-01 | 01/10/05 | Rating Consultant Plan Submittals | 6-3.03(02) |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
04-20 | 12/21/04 | Barrier Flare Rates | 49-9.0 | ||
04-19 | 12/20/04 | Sidewalk Curb Ramps & Sidewalk Transitions | 51-1.08 | ||
04-18 | 11/22/04 | FHWA Project Oversight | 40-7.0 | ||
04-17 | 11/15/04 | Retrofit Thrie-beam Bridge Railing | 61-6.01(02) | 05-05 | |
04-16 | 11/15/04 | Thrie-beam Guardrail & Transitions | 49-4.03 | ||
04-15 | 11/15/04 | Crest Vertical Curves to Remain in Place | 55-4.04(03) | 05-04 | |
04-14 | 10/12/04 | Notification Procedure for Temporary Land Acquisition Suspension | 85-3.03(01) | ||
04-13 | 10/12/04 | Intersecting Welds in Structural Steel Members | 64-8.02 | ||
04-12 | 10/12/04 | Fracture-critical Structural Steel Members | 64-1.07 | ||
04-11 | 10/12/04 | Empirical design of concrete bridge decks | 61-3.0 | ||
04-10 | 10/12/04 | Wingwalls & headwalls for precast concrete box culvert | 31-3.06 | ||
04-09 | 10/12/04 | Bridge loading rating policy | 14-2.03(07) | ||
04-08 | 10/12/04 | Underground storage tank removal | 14-2.01(07) | ||
04-07 Adv 04-07 Pol |
10/12/04 | Paving work at structure installation | 17-3.03 | ||
04-06 | 08/04/04 | Subgrade treatment | 17-3.02 | 10-15 | |
04-05 | 05/26/04 | HS 25 loading for new & replacement bridges | 60-3.02 | ||
04-04 | 05/13/04 | Partial 3R design policy | Ch 56 | ||
04-03 Adv 04-03 Pol |
5/13/04 | Pavement design policy | Ch 52 | 14-06 | |
04-02 | 05/12/04 | Temporary R/W for drive construction | 85-5.01(01) | ||
04-01 | 02/20/04 | Intersection sight distance at divided roadway | 49-6.01 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
03-19 | 12/08/03 | Drainage in curbed section | 45-1.05(04) | ||
03-18 | 12/08/03 | Guardrail at culverts | 49-3.03(01) | ||
03-17 | 10/15/03 | Reinforced concrete bridge approach | 17-4.09 | ||
03-16 Adv 03-16 Pol |
10/02/03 | Pavement milling | 04-03 | ||
03-15 | 10/02/03 | Sidewalk curb ramps for partial 3R work | 56-4.0 | ||
03-14 | 09/30/03 | IDEM Rule 5 submission for erosion control plan | 9-2.05(06) | ||
03-13 | 09/10/03 | Guardrail end treatment type II pay limits | 49-5.04(01) | ||
03-12 | 08/20/03 | Specifications conflicts | 19-2.02 | ||
03-11 Adv 03-11 Pol |
08/12/03 | Rest-area water treatment | 51-2.01(02) | ||
03-10 | 08/07/03 | Environmental permits | 9-2.02(09) | ||
03-09 | 07/10/03 | HMA pavement ESAL ranges | 52-9.02(03) | 14-06 | |
03-08 | 07/02/03 | Interstate-highway lane closures | 82-6.01 | ||
03-07 | 07/02/03 | Context-sensitive design policy | Unknown | ||
03-06 | 06/06/03 | HMA pavement ESAL ranges | 03-09 | ||
03-05 Adv 03-05 Pol |
05/08/03 | Partial 3R design policy | 04-04 | ||
03-04 | 05/07/03 | Revised pay items | 20-2.02(02) | ||
03-03 | 04/15/03 | Compatibility of drainage structures & castings | 36-2.14 | ||
03-02 | 03/05/03 | Three-sided drainage structures | NYA | RSPs 723-R-282 & 723-R-282f | |
03-01 | 02/17/03 | Sidewalk curb ramps | 04-19 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
02-11 | 12/05/02 | Sag vertical curve equations for undercrossing | 44-3.02(04) | ||
02-10 | 09/09/02 | Traffic maintenance plan for roadway under overpass work | 82-6.01 | ||
02-09 | 08/14/02 | Status of design memoranda | 05-03 | ||
02-08 | 07/31/02 | Subgrade Treatment | 04-06 | ||
02-07 | 07/19/02 | 2001 AASHTO “Green Book” affects on Design Manual | Varies | ||
02-06 | 07/09/02 | PCCP joints | 52-9.03 | 14-06 | |
02-05 | 06/13/02 | Pavement design policy | 04-03 | ||
02-04 Adv 02-04 Pol |
06/07/02 | Subgrade treatment | 02-08 | ||
02-03 Adv 02-03 Pol |
06/07/02 | Shoulder corrugations | 45-1.02(06) | ||
02-02 Adv 02-02 Pol |
06/07/02 | HMA pavement design | 02-05 | ||
02-01 | 01/07/02 | LED traffic signal indicator | 77-4.04 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
01-14 | 12/10/01 | Water main & sanitary sewer contract work | Unknown | ||
01-13 | 11/15/01 | Use of english measurement units | Varies | ||
01-12 | 10/15/01 | Contract-specific standard-drawings index | 19-1.04 | ||
01-11 | 08/01/01 | Three-sided drainage structures | 03-02 | ||
01-10 Adv 01-10 Pol |
08/01/01 | Subgrade treatment & soil chemical modification | 02-04 | ||
01-09 | 06/13/01 | Construction-zone energy-absorbing terminal | 82-4.02(03) | ||
01-08 | 06/13/01 | Construction-zone GREAT unit | 01-09 | ||
01-07 | 06/05/01 | Status of design memoranda | 02-09 | ||
01-06 | 05/23/01 | Use of english measurement units | Varies | 01-13 | |
01-05 | 05/21/01 | Curing concrete bridge deck or RCBA | 62-1.01 | ||
01-04 | 05/21/01 | Bridge future wearing surface dead load | 60-2.05 | ||
01-03 | 05/21/01 | Use of english measurement units | 01-06 | ||
01-02 Adv 01-02 Pol |
05/14/01 | Impact attenuators | 49-6.0 | ||
01-01 | 02/07/01 | Concrete barrier railing | 05-02 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
00-19 Adv 00-19 Pol |
12/11/00 | Temporary erosion & sediment control | Ch. 37 | ||
00-18 | 10/16/00 | Status of design memoranda | 01-07 | ||
00-17 | 10/06/00 | Three-sided drainage structures | 01-11 | ||
00-16 | 10/06/00 | Riprap ditch | 30-3.03(02) | ||
00-15 | 10/06/00 | Design data on plans title sheet | 14-3.04(06) | ||
00-14 | 10/06/00 | ESALs determination | 02-05 | ||
00-13 | 09/22/00 | Nested guardrail & cable terminal anchor | 49-5.03 | ||
00-12 Adv 00-12 Pol |
09/22/00 | Guardrail over large culvert | 49-5.03 | ||
00-11 | 09/22/00 | Three-sided drainage structures | 00-17 | ||
00-10 | 09/13/00 | NCHRP 350 bridge railings & transitions | 05-05 | ||
00-09 Adv 00-09 Pol |
06/07/00 | Rating Consultant Plan Submittals | 02-05 | ||
00-08 | 05/30/00 | Termination of new HMA pavement | 56-4.01 | ||
00-07 | 05/30/00 | Permanent easement for maintenance of legal ditch | 85-5.03 | ||
00-06 | 05/30/00 | Application of environmental documents | 7-1.01 | ||
00-05 | 05/30/00 | Environmental permit requirements | 9-2.0 | ||
00-04 | 05/31/00 | Status of design memoranda | 00-18 | ||
00-03 Adv 00-03 Pol |
03/01/00 | Impact attenuators | 01-02 | ||
00-02 Adv 00-02 Pol |
03/01/00 | Guardrail end treatments | 49-5.04(01) | ||
00-01 Adv 00-01 Pol |
03/01/00 | Positive guidance for crossed-over two-lane two-way traffic on multi-lane highway construction-zone | 82-4.02 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
99-19 | 12/21/99 | Contract-specific standard-drawings index | 01-12 | ||
99-18 | 12/15/99 | Underdrain table | 02-05 | ||
99-17 | 11/16/99 | Contract documents submittal | 19-3.03 | ||
99-16 Adv 99-16 Pol |
11/15/99 | NCHRP 350 bridge railings & transitions | 00-10 | ||
99-15 | 09/22/99 | Backfill behind bridge end bent | 17-2.08 | ||
99-14 | 09/21/99 | NHS routes maps | 40-1.03(01) | ||
99-13 Adv 99-13 Pol |
08/30/99 | Underdrains | 02-05 | ||
99-12 | 08/18/99 | HMA resurfacing | 03-05 | ||
99-11 | 05/26/99 | Subsurface investigation summary | 18-1.05 | ||
99-10 | 05/26/99 | Concrete deck slab permanent forms | 61-4.03 | ||
99-09 Adv 99-09 Pol |
04/26/99 | Impact attenuators | 00-03 | ||
99-08 | 04/15/99 | FHWA project oversight | 04-18 | ||
99-07 | 03/23/99 | Portland cement concrete pavement | 02-05 | ||
99-06 | 03/18/99 | GREAT unit | 00-03 | ||
99-05 | 03/17/99 | Reinforced concrete bridge approach | 03-17 | ||
99-04 | 03/17/99 | B/P profilograph | 17.3.01 | ||
99-03 | 03/17/99 | Traffic control for construction operations | 83-4.0 | ||
99-02 | 03/17/99 | NCHRP 350 guardrail, GRETs, bridge railing transitions | 49-4.03 | ||
99-01 | 1/19/99 | Use of 1999 Standard Specifications | 05-23 |
Memo Number | Issue Date | Subject | Design Manual Ch.-Sec. |
Attachments | Super- seding Memo |
98-12 | 11/30/98 | B/P structural steel members; stud shear connectors | 17-4.01 | ||
98-11 | 11/30/98 | B/P concrete structural members | 17-4.01(02) | ||
98-10 | 11/23/98 | NCHRP 350 guardrail post requirements | 99-02 | ||
98-09 Adv 98-09 Pol |
11/23/98 | IDEM Section 401 Water Quality Certification | 00-03 | ||
98-08 | 11/16/98 | Profile-wall PVC pipe | 28-6.05 | ||
98-07 | 09/25/98 | Backfill behind bridge end bent | 99-15 | ||
98-06 Adv 98-06 Pol |
08/01/98 | Three-sided drainage structure scour protection | 00-17 | ||
98-05 Adv 98-05 Pol |
07/15/98 | Utilities coordination process | Ch. 10 | ||
98-04 | 06/22/98 | Pile loads table | 66-3.04 | ||
98-03 | 06/15/98 | GREAT unit | 00-03 | ||
98-02 | 06/15/98 | NCHRP 350 guardrail, GRETs, bridge railing transitions | 00-02 | ||
98-01 Adv 98-01 Pol |
06/10/98 | New-pipes concept | 28-6.0 | ||
98-00 | 06/03/98 | Proposing changes to Standard Documents or Proposing New Standard Documents | Varies |