TITLE 675 FIRE PREVENTION AND BUILDING SAFETY COMMISSION
Agency Correction
LSA Document #07-476(AC)
(1) In
675 IAC 13-2.5-9(2), delete "Decoration
[sic, Decorations] and trim" and insert "Decorative materials and trim".
(6) In
675 IAC 13-2.5-17(14), insert "Add TABLE 1613.5.4 MAXIMUM VALUES FOR SDS AND SD1 to read as follows:
TABLE 1613.5.4. - MAXIMUM VALUES FOR SDS AND SD1
| | |
Site Class | SDS | SD1 |
A | 0.30 | 0.12 |
B | 0.38 | 0.15 |
C | 0.45 | 0.25 |
D | 0.55 | 0.32 |
E | 0.75 | 0.50 |
F | Note 1 | Note 1 |
Note 1: Site-specific geotechnical investigation and dynamic site response analyses shall be performed to determine appropriate values.".
Filed with Publisher: July 3, 2008, 8:10 a.m.
Under IC 4-22-2-38(g)(2), this correction takes effect 45 days from the date and time filed with the Publisher.
Posted: 07/16/2008 by Legislative Services Agency
DIN: 20080716-IR-675070476ACA