(2) Except as provided in clauses (C) through (F), Alcoa shall obtain two (2) duplicate representative samples of the delisted waste each quarter and analyze them for the constituents listed in Table 1 as follows:
(A) Constituents must be extracted using the following:
(i) Method 1311, Toxicity Characteristic Leaching Procedure (TCLP)*.
(ii) Method 1330A, Oily Waste Extraction Procedure*, if oil and grease levels exceed ten thousand (10,000) milligrams per kilogram.
(iii) Method 3060A, Alkaline Digestion for Hexavalent Chromium*.
(B) Constituents must be analyzed using the following:
(i) Method 6010B, Inductively Coupled Plasma-Atomic Emission Spectrometry* or Method 6020, Inductively Coupled Plasma-Mass Spectrometry*.
(ii) Method 7470A, Mercury in Liquid Waste (Manual Cold-Vapor Technique)*.
(iii) Method 7196A, Hexavalent Chromium (Colorimetric)*.
(C) For constituents other than hexavalent chromium, if the relative percent difference between the two (2) samples is forty percent (40%) or less for the first four (4) quarters, then Alcoa may obtain and analyze one (1) representative sample of the delisted waste each following quarter. The relative percent difference (RPD) is calculated for each constituent and equals one hundred (100) times the absolute value of the difference between the results divided by the average of the results, as follows:
where x1 equals sample results and x2 equals duplicate results.
(D) If the level of hexavalent chromium in the sample or duplicate sample is less or equal to ten and zero-tenths (10.0) milligrams per kilogram during the first four (4) quarters, then Alcoa may obtain and analyze one (1) representative sample of the delisted waste for hexavalent chromium each following quarter.
(E) If the level of hexavalent chromium in the sample or duplicate sample is greater than ten and zero-tenths (10.0) milligrams per kilogram, then Alcoa must calculate the relative percent difference as described in clause (C). If the relative percent difference between the two (2) samples is forty percent (40%) or less during the first four (4) quarters, then Alcoa may obtain and analyze one (1) representative sample of the delisted waste for hexavalent chromium each following quarter.
(F) If duplicate results for any constituent exceed forty percent (40%) relative percent difference, Alcoa must continue to analyze duplicate samples for that constituent for an additional two (2) quarters beyond the initial four (4) quarters. If the results still exceed forty percent (40%) relative percent difference after the additional two (2) quarters, Alcoa must continue to analyze duplicate samples for that constituent until authorized by the department to analyze one (1) sample each quarter.
(G) If any sample result shows any constituent listed in Table 1 at or above fifty percent (50%) of the delisting level for that constituent, then Alcoa must analyze two (2) duplicate samples each quarter until authorized by the department to analyze one (1) sample each quarter.
(H) Nothing in this section prohibits Alcoa from requesting at any time that the solid waste management board modify this section to allow less frequent verification testing.
(3) If waste testing or other information available to Alcoa shows that any constituent in Table 1 has exceeded the delisting level for that constituent, or Alcoa makes changes in the Warrick Operations that cause hazardous constituents listed in Table 1 to exceed the delisting level for that constituent, Alcoa must do all of the following:
(A) Notify the department in writing within ten (10) days of first possessing or being made aware of such data.
(B) Demonstrate that the waste continues to meet all delisting levels in Table 1.
(C) Manage the waste as hazardous waste until Alcoa receives written approval from the commissioner to resume managing the waste under this exclusion.
(4) Alcoa must submit an annual report that summarizes the data obtained through quarterly verification testing required by subdivision (2) to the department by February 1 of the following year. The report must include the results of each required analysis for the previous calendar year.
(5) Alcoa must compile, summarize, and maintain records of operating conditions and analytical data. The records must be:
(A) maintained for a minimum of five (5) years; and
(B) made available for inspection by the department during normal working hours.
(6) All data required by this section must be accompanied by a signed copy of the certification statement in 40 CFR 260.22(i)(12).
(7) The delisted waste must be disposed of in a:
(A) municipal solid waste landfill permitted under
(B) hazardous waste disposal facility permitted under this article.
(8) If, at any time after disposal of the delisted waste, Alcoa possesses or is otherwise made aware of any data, including, but not limited to, leachate data or ground water monitoring data, or any other data relevant to the delisted waste indicating that any constituent identified in Table 1 is at a level in the leachate that is higher than the specified delisting level, then Alcoa must report such data in writing to the department within ten (10) days of first possessing or being made aware of that data.
(9) No more than five thousand two hundred fifty (5,250) short tons of delisted waste may be disposed of in any calendar year under this exclusion.
*Test methods referenced in this rule are found in U.S. Environmental Protection Agency Publication SW-846, "Test Methods for Evaluating Solid Wastes, Physical/Chemical Methods", Third Edition, available from the Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, Pennsylvania 15250-7954, (202) 783-3238.
(Solid Waste Management Board;
LSA Document #07-552(F)
Proposed Rule:
Hearing Held: January 15, 2008
Approved by Attorney General: March 28, 2008
Approved by Governor: March 31, 2008
Filed with Publisher: April 1, 2008, 10:11 a.m.
Documents Incorporated by Reference: U.S. Environmental Protection Agency Publication SW-846, "Test Methods for Evaluating Solid Wastes, Physical/Chemical Methods", Third Edition: Method 1311, Toxicity Characteristic Leaching Procedure (TCLP); Method 1330A, Oily Waste Extraction Procedure; Method 3060A, Alkaline Digestion for Hexavalent Chromium; Method 6010B, Inductively Coupled Plasma-Atomic Emission Spectrometry; Method 6020, Inductively Coupled Plasma-Mass Spectrometry; Method 7196A, Hexavalent Chromium (Colorimetric); Method 7470A, Mercury in Liquid Waste (Manual Cold-Vapor Technique)
Small Business Regulatory Coordinator: Christina Lowry, IDEM Compliance and Technical Assistance Program, OPPTA - MC60-04, 100 North Senate Avenue, W-041, Indianapolis, IN 46204-2251, (317) 234-1191, clowry@idem.in.gov
Small Business Assistance Program Ombudsman: Megan Tretter, IDEM Small Business Assistance Program Ombudsman, MC 50-01– IGCN 1301, 100 North Senate Avenue, Indianapolis, IN 46204-2251, (317) 234-3386, mtretter@idem.in.gov
Posted: 04/30/2008 by Legislative Services Agency DIN: 20080430-IR-329070552FRA
Composed: Apr 28,2024 12:18:40PM EDT
A PDF version of this document.
|